Описание оборудования | |
|---|---|
| Reader with protective housing and PROFINET interface | |
General specifications | |
| Passage speed | ? 12.5 m/s |
| Measuring range | max. 314.5 m |
| Free tolerances to code rail | horizontal: 28 mm ( ± 14 mm ) vertical: 25.5 mm ( +11.5mm/-14mm ) |
| Resolution | ± 0.4 mm (1,250 positions/m) |
Functional safety related parameters | |
| MTTFd | 50 a |
| Mission Time (TM) | 10 a |
| Diagnostic Coverage (DC) | 0 % |
Indicators/operating means | |
| LED green | PROFINET link To: PROFINET connection OK |
| LED yellow | PROFINET RX/TX Flashing: data transfer |
| LED red | PROFINET communication To: communication error |
| LED red/green | Status indication Green: code rail detected, normal function Red: system error Flashing red: no code rail detected |
Electrical specifications | |
| Operating voltage | 10 ... 30 V DC |
| Power consumption | 15 W |
Interface | |
| Interface type | 100 BASE-TX |
| Data output code | binary code |
| Protocol | PROFINET IO Real-Time (RT) Conformance class B |
| Transfer rate | 100 MBit/s |
Standard conformity | |
| Emitted interference | EN 61000-6-4:2007+A1:2011 |
| Noise immunity | EN 61000-6-2:2005 |
| Shock resistance | EN 60068-2-27:2009 |
| Vibration resistance | EN 60068-2-6:2008 |
Approvals and certificates | |
| CSA approval | cCSAus Certified, General Purpose Class 2 power source |
| CCC approval | CCC approval / marking not required for products rated ?36 V |
Ambient conditions | |
| Operating temperature | -40 ... 60 °C (-40 ... 140 °F) |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
Mechanical specifications | |
| Connection type | 8-pin, M12 x 1 connector, Y-coded |
| Degree of protection | IP67 / IP69 |
| Material | |
| Mass | 1000 g |
| Note | The reader must not be operated without the protective housing! |
8 (029) 555-8-000 | |
8 (044) 555-8-000 | |
8 (017) 255-8-000 |