Reader with protective housing and PROFINET interface | |
General specifications | |
Passage speed | ? 12.5 m/s |
Measuring range | max. 314.5 m |
Free tolerances to code rail | horizontal: 28 mm ( ± 14 mm ) vertical: 25.5 mm ( +11.5mm/-14mm ) |
Resolution | ± 0.4 mm (1,250 positions/m) |
Functional safety related parameters | |
MTTFd | 50 a |
Mission Time (TM) | 10 a |
Diagnostic Coverage (DC) | 0 % |
Indicators/operating means | |
Display | Display module, 6-digit , adaptable to installation position |
LED green | PROFINET link To: PROFINET connection OK |
LED yellow | PROFINET RX/TX Flashing: data transfer |
LED red | PROFINET communication To: communication error |
LED red/green | Status indication Green: code rail detected, normal function Red: system error Flashing red: no code rail detected |
Electrical specifications | |
Operating voltage | 10 ... 30 V DC |
Power consumption | 15 W |
Interface | |
Interface type | 100 BASE-TX |
Data output code | binary code |
Protocol | PROFINET IO Real-Time (RT) Conformance class B |
Transfer rate | 100 MBit/s |
Standard conformity | |
Emitted interference | EN61000-6-4:2007+A1:2011 |
Noise immunity | EN 61000-6-2:2005 |
Shock resistance | EN 60068-2-27:2009 |
Vibration resistance | EN 60068-2-6:2008 |
Approvals and certificates | |
CSA approval | cCSAus Certified, General Purpose Class 2 power source |
CCC approval | CCC approval / marking not required for products rated ?36 V |
Ambient conditions | |
Operating temperature | -40 ... 60 °C (-40 ... 140 °F) |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
Mechanical specifications | |
Connection type | 8-pin, M12 x 1 connector, Y-coded |
Degree of protection | IP67 / IP69 |
Material | |
Mass | 1000 g |
Note | The reader must not be operated without the protective housing! |