Basic data | |||||||
---|---|---|---|---|---|---|---|
Series | MC330 | ||||||
Functions | |||||||
Functions | Integration in control circuits up to category 4 in accordance with EN ISO 13849, Locking device without guard interlocking according to ISO 14119, Safety system in combination with an evaluation unit such as the MSI-MC311 safety relay or the MSI 100 or MSI 200 safety controller. | ||||||
Characteristic parameters | |||||||
Mission time | 20 years, EN ISO 13849-1 | ||||||
Category | Up to 4, depending on evaluation, 1 sensor connected, EN ISO 13849 | ||||||
B10d | 20,000,000 number of cycles | ||||||
Electrical data | |||||||
Protective circuit | Short circuit protected, Via e.g. MSI-MC311, MSI 400, Current limitation | ||||||
Contact allocation | 2NO | ||||||
Contact type | Reed contacts (magnetically sensitive) | ||||||
Requirement on the voltage supply when used acc. to cULus (UL 508) | Class 2 Circuits | ||||||
Outputs | |||||||
Max. switching voltage | 27 V AC/DC | ||||||
Switching current, max. | 100 mA | ||||||
Requirement on the voltage supply when used acc. to cULus (UL 508) | Class 2 Circuits | ||||||
Timing | |||||||
Response time | 3 ms | ||||||
Connection | |||||||
Number of connections | 1 Piece(s) | ||||||
Connection 1 | |||||||
Type of connection | Cable with wire-end sleeves | ||||||
Function | Contact connection | ||||||
Cable length | 5,000 mm | ||||||
Sheathing material | PVC | ||||||
Cable color | Gray | ||||||
Number of conductors | 4 -wire | ||||||
Number of connections | 1 Piece(s) | ||||||
Mechanical data | |||||||
Design | Cylindrical | ||||||
Thread size | M30 x 3.5 mm | ||||||
Dimension | 36 mm | ||||||
Housing material | Plastic, Glass fiber reinforced (PPS), self-extinguishing | ||||||
Net weight | 345 g | ||||||
Housing color | Red | ||||||
Type of fastening | Mounting thread | ||||||
Installation position | Arbitrary, provided housing markings are aligned | ||||||
Switch type | Interlock device without guard interlocking, ISO 14119 | ||||||
Approach actuation directions | 3-dimensional | ||||||
Mechanical life time | 10,000,000 actuation cycles | ||||||
External actuator | Magnetically coded | ||||||
Cut-out point (OFF), min. | 15 mm | ||||||
Assured cut-out distance (Sar), min. | 18 mm | ||||||
Assured cut-in distance (Sao), max. | 6 mm | ||||||
Switching tolerance (without ferromagnetic materials in immediate vicinity) | -1 ... 1 mm | ||||||
Distance to other magnetic sensors, min. | 50 mm | ||||||
Approach speed, min. | 0.05 m/s | ||||||
Environmental data | |||||||
Ambient temperature, operation | -20 ... 70 °C | ||||||
Degree of contamination |